Here are the safety precautions for handling BHMTPMPA:

Personal protective equipment: Wear appropriate personal protective equipment, including chemical - resistant gloves, safety goggles, and protective clothing, to prevent BHMTPMPA from coming into contact with the skin and eyes. In case of contact with the skin, wash it immediately with plenty of water. If it gets into the eyes, rinse them thoroughly with clean water and seek medical attention.
Ventilation: Use BHMTPMPA in a well - ventilated area to ensure good air circulation and avoid the inhalation of its vapors or mist. If used in a confined space, appropriate ventilation equipment should be installed.
Storage: Store BHMTPMPA in a cool, dry place, away from direct sunlight, heat sources, and ignition sources. Keep it in a tightly sealed container to prevent leakage and contamination. It should be stored separately from oxidizing agents, alkalis, and other incompatible substances to avoid chemical reactions.
Handling and mixing: When handling BHMTPMPA, follow the recommended procedures and dosages. Use appropriate handling tools and equipment to avoid splashing and leakage. Do not mix it with other chemicals without permission, as this may cause unexpected chemical reactions. During the mixing process, add BHMTPMPA slowly and stir evenly to avoid local over - concentration.
Environmental protection: Avoid discharging BHMTPMPA into the environment. In case of spills or leaks, take immediate measures to clean up and prevent it from entering water bodies, soil, or sewers. Dispose of waste BHMTPMPA in accordance with local environmental regulations.
Emergency response: Be familiar with the emergency response procedures in case of accidents. Have emergency response equipment and materials, such as absorbent materials, neutralizing agents, and fire - fighting equipment, on hand. In case of a fire or explosion, evacuate immediately and call the fire department. In case of contact with the skin or eyes, or inhalation of BHMTPMPA, provide first - aid treatment immediately and seek medical attention.

It is important to note that specific safety precautions may vary depending on the concentration and application of BHMTPMPA. It is recommended to refer to the safety data sheet (SDS) provided by the manufacturer for detailed and specific safety information.

At the end of its use, PAPEMP should be disposed of in accordance with the following methods and requirements:

Recovery and reuse: If possible, consider recovering and reusing PAPEMP. Some industrial processes may have the conditions to separate and purify PAPEMP from the used solution for reuse, which can reduce waste and costs.
Chemical treatment: For solutions containing [PAPEMP][1] that cannot be reused, chemical treatment methods can be adopted. For example, adding appropriate chemical agents to react with PAPEMP to break down its molecular structure and convert it into less harmful substances. Specific treatment agents and processes need to be determined according to the characteristics of PAPEMP and the composition of the solution.
Treatment by professional waste disposal companies: If the above methods are not feasible, it is necessary to entrust professional waste disposal companies to handle PAPEMP. These companies have the necessary equipment and technical capabilities to safely and properly dispose of chemical waste. When choosing a waste disposal company, make sure that it has the corresponding qualifications and compliance records to ensure that the disposal process meets environmental protection requirements.
Compliance with relevant regulations: No matter which disposal method is used, it must comply with local environmental protection regulations and relevant laws. This includes proper packaging and labeling of waste, reporting and record - keeping of disposal activities, and ensuring that the disposal process does not cause pollution to the environment and harm to human health.

https://www.kairuiwater.com/papemp.htm

Here are the safety precautions for using PAPEMP:

Personal protection: Wear appropriate personal protective equipment, including chemical - resistant gloves, safety goggles, and protective clothing, to prevent contact with the skin and eyes. If the product comes into contact with the skin, immediately wash it with plenty of water. If it gets into the eyes, rinse them thoroughly with clean water and seek medical attention.
Ventilation: Use PAPEMP in a well - ventilated area to avoid the build - up of vapors or fumes. Ensure that there is good air circulation to prevent inhalation of any potentially harmful substances.
Storage: Store PAPEMP in a cool, dry place, away from direct sunlight and heat sources. Keep it in a tightly sealed container to prevent leakage and contamination. Avoid storing it near flammable, explosive, or reactive substances.
Handling and mixing: When handling [PAPEMP][2], follow the recommended procedures and dosages. Do not mix it with other chemicals without proper knowledge and authorization, as this may cause chemical reactions or reduce its effectiveness. Use appropriate mixing equipment and ensure that the mixing process is carried out under controlled conditions.
Environmental protection: Dispose of any waste or unused PAPEMP properly, in accordance with local environmental regulations. Do not discharge it into water bodies or the environment without treatment, as it may have an impact on the ecological environment.
Emergency response: Be familiar with the emergency response procedures in case of spills, leaks, or other accidents. Have appropriate emergency response equipment and materials on hand, such as absorbent materials and neutralizing agents. In the event of a spill, immediately isolate the area, prevent the spread of the substance, and clean it up according to the proper procedures.

It is important to note that specific safety precautions may vary depending on the concentration and application of PAPEMP. It is recommended to refer to the safety data sheet (SDS) provided by the manufacturer for detailed and specific safety information.

PAPEMP (Poly (amino - phosphonic acid) ethyl methacrylate) is commonly used in the following applications:

  • Industrial water treatment: It is used in industrial circulating water systas, boilers, and cooling towers. PAPEMP can effectively inhibit the formation of scales, such as calcium carbonate and calcium sulfate, on the surfaces of heat - exchange equipment and pipelines. By preventing scale deposition, it improves the heat - transfer efficiency of the equipment, reduces energy consumption, and prolongs the service life of the equipment. Additionally, it has some corrosion - inhibition properties, which can protect the metal surfaces of the water - treatment systa from being corroded by the water medium.
  • Oil - field water treatment: In the oil - field industry, PAPEMP is applied to treat oil - field produced water. It helps prevent the formation of scales in the water, which can otherwise block the oil - field pipelines and equipment. This is crucial for maintaining the normal operation of oil - field production facilities, improving production efficiency, and reducing maintenance costs.
  • Paper - making industry: In the paper - making process, PAPEMP is used as a scale - inhibition and corrosion - inhibition agent. It can prevent the formation of scales on the surface of paper - making equipment, such as paper machines and pulp storage tanks. This helps to improve the quality of the paper by reducing the occurrence of defects caused by scale deposition. Moreover, its corrosion - inhibition effect helps to protect the metal components of the paper - making equipment, ensuring the stable operation of the production line.

PBTC is widely used in circulating cooling water systems and oilfield supply water systems.

PBTC can be used as a high efficient scale and corrosion inhibitor in situations of high temperature, high hardness, high alkali and high concentration index. In lavation fields, PBTC is used as chelating agent and metal detergent.

PBTC is usually used together with zinc salt, copolymer, organophosphine, imidazole and other water treatment chemicals. When used alone, the dosage of 5-15mg/L is preferred.

https://www.kairuiwater.com/pbtc.htm